Fire & Safety

Industrial Fire & Safety

Zener Fire & Security provides comprehensives fire safety solutions for businesses. Our unique combination of products and services allow us to create customized solutions designed to help protect their buildings, factories, equipment, properties and people, around the clock.

detection
Fire & Gas Detection Systems
Fully integrated fire & gas detection solutions for the industrial segment are carried out by our highly experienced and trained engineers. Flame detection, gas detection coupled with sophisticated control and annunciation systems are provided to protect assets and save human lives.
mist
Fire Suppression Systems
We are leaders in suppression systems. We design, install, test, commission, service and maintain wide range of Fire Suppression Systems such as FM200, NOVEC, Argonite, HPCO2, LPCO2, High Pressure Water Mist, Dry Chemical, Wet Chemical and FirePASS systems. Our factory trained & certified engineers carryout in house Design, Drawings & Calculations in accordance with the requirements of International Standards & using latest softwares.
fire fighting
Fire Fighting and Protection Systems
Fire-fighters and first-responders in the industrial and government/defense areas rely on our systems for fast and efficient fighting of fires. We specialise in designing effective fire fighting and control systems for power plant, oil & gas facilities, industrial facilities etc. Our project management skills ensure our ability to execute turnkey projects and provide solution to all our clients from one source.
fire pump
Fire water pump sets

The Fire fighting pumps are designed in accordance with NFPA standards and local civil defence requirements. The fire pumps capacity shall be decided as per NFPA or client requirements. The fire pump sets consists of Electric motor driven Fire pumps, Diesel engine driven fire pumps, Pressure maintaining Jockey pumps, fire pump controllers, Pressure vessels, Flow meter, Isolation valves, check valves, pressure relief valves, etc., as per requirements.

Fire pumps can be horizontal split-case type or vertical turbine type as per specification requirement and also suitable for potable water or seawater application as per requirement.The Fire pumps sets are used commonly in the Power generation plants, substations, Container terminals, oil refinery plants, etc.

hydrant
Hydrant System

Hydrant system are designed and provided in accordance with NFPA standards and local civil defence requirements for Automatic operation. The discharge flow rate depends upon the system type – Class I / Class II / Class III as per NFPA or client requirements. The system consists of Fire water pumps, Fire ring main (Aboveground or Underground type), Isolation valves, Wet or Dry barrel hydrants, Fire Equipment cabinets complete with accessories. Fire ring main is routed in the aboveground or underground as per project requirements. Aboveground pipe types are normally carbon steel pipes and underground pipe types are ductile iron pipes, GRE pipes, GRP pipes, HDPE pipes, etc.

Fire ring main are designed for potable water or seawater purpose and are kept under system pressure by Fire water pumps. Isolation valves are provided in order to sectionalize the fire ring main in case of maintenance. The hydrants are located at strategic locations as per NFPA or specification requirement to cover the buildings and equipment relevant to be protected. Fire equipment cabinets are provided near the hydrants with complete accessories such as fire hoses, hose nozzles, fire axe, crow bar, wrenches, etc.

waterspray
Deluge Water Spray System

Deluge water spray system are designed and provided in accordance with NFPA standards and local civil defence requirements for Automatic operation. The design density of discharge depends upon the area to be protected. The system consists of Fire water pumps, Deluge valve, isolation valve, spray nozzles, quartzoid bulb detectors and piping etc. Deluge valves can be actuated either hydraulically or electrical based on the required and design philosophy.

The system is used commonly for protection of Transformers, Fuel oil storage tanks, Lube or hydraulic oil skid, Cable basement or cable room and for other equipment.

foampump
Foam System

Foam system are designed and provided in accordance with NFPA standards and local civil defence requirements for Automatic operation. The design density of discharge depends upon the area to be protected. The system consists of Fire water pumps, Deluge valve, foam pourers, proportioners, foam chambers, isolation valve, spray nozzles, quartzoid bulb detectors, Foam pump or Foam proportioner, Foam storage tank, foam solution and piping etc.

The system is used commonly for protection of Diesel generators, Fuel oil storage tanks, Fuel oil pump shelter, Lube oil unit, Hydraulic oil unit, etc.

1% / 3% / 6% AFFF, 3% / 6% AFFF-AR, 3% / 6% FP, 3% / 6% FFFP, 3% / 6% FFFP-AR can be used in the fixed systems.

skid
Skids For Offshore , Oil & Gas Industry

Zener Specializes in custom built skid complying to meet the stringent specifications of the offshore, oil & gas industry.

We design, manufacture, fabricate and assemble deluge skids, foam skids, sprinkler skid, FM 200 and NOVEC skids, water mist skids etc.

All skids are designed and fabricated in house with stringent QA/QC Standards